Does the 2007 Gillig Low Floor have recalls?

8 NHTSA recall campaigns on file. Recall repairs are free at franchised dealers.

18V418000LightingJune 20, 2018 · 25,579 units

Defect

Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."

Consequence

The reduced visibility of the turn signals can increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

17V119000LightingFebruary 24, 2017 · 17,056 units

Defect

Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."

Consequence

The reduced visibility of the turn signals may increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

14V358000EngineJune 23, 2014 · 648 units

Defect

Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.

Consequence

If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.

Remedy

Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1-800-735-1500.

09V368000LightingSeptember 28, 2009 · 1,053 units

Defect

GILLIG CORPORATION IS RECALLING CERTAIN MODEL YEAR 2001 THROUGH 2009 TRANSIT BUSES MANUFACTURED BETWEEN JANUARY 2001 AND SEPTEMBER 2009 EQUIPPED WITH LUMINATOR HORIZON LED SIDE DESTINATION SIGNS. THE CONNECTOR BOARD CAN CORRODE DUE TO AN ACCUMULATION OF MOISTURE UNDER THE CONNECTOR.

Consequence

A SHORT COULD OCCUR, POSSIBLY CAUSING SMOKE AND FIRE.

Remedy

GILLIG WILL NOTIFY OWNERS AND LUMINATOR WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SPETEMBER 29, 2009. OWNERS MAY CONTACT LUMINATOR AT 1-972-516-3033 OR GILLIG FIELD SERVICES AT 1-800-735-1500.

08V175000SuspensionApril 16, 2008 · 31 units

Defect

GILLIG IS RECALLING 31 MY 2007 29 FOOT LOW FLOOR TRANSIT BUSES EQUIPPED WITH SAF- HOLLAND ADL SERIES REAR SUSPENSIONS. IN SOME INSTANCES THE TRANSVERSE BEAM WAS NOT PROPERLY WELDED WHICH COULD RESULT IN A FAILURE OF THE WELD.

Consequence

IF THE WELD FAILS, VEHICLE STABILITY WHILE CORNERING COULD BE AFFECTED RESULTING IN LOSS OF VEHICLE CONTROL, POSSIBLY RESULTING IN A CRASH. IN ADDITION, THE TRANSVERSE BEAM COULD DROP TO THE GROUND CAUSING SPARKS THAT COULD CAUSE A FIRE HAZARD.

Remedy

GILLIG IS WORKING WITH SAF HOLLAND TO HAVE A VISUAL INSPECTION OF THE ADL TRANSVERSE BEAM PERFORMED. IF A WELD DEFECT IS IDENTIFIED, SAF HOLLAND WILL PROVIDE A SERVICE REPLACEMENT KIT THAT CONTAINS A NEW TRANSVERSE BEAM, ALL NECESSARY INSTALLATION HARDWARE, BEAM REPLACEMENT AND INSTRUCTIONS FREE OF CHARGE (PLEASE SEE 08E031). THE RECALL BEGAN ON APRIL 29, 2008. OWNERS MAY CONTACT GILLIG AT 1-510-264-5031 OR SAF-HOLLAND AT 1-231-773-3271.

08V008000BrakesJanuary 9, 2008 · 249 units

Defect

ON CERTAIN TRANSIT BUSES EQUIPPED WITH GRAHAM-WHITE AIR DRYERS, THE AIR DRYER TIMER MODULES MAY ALLOW SUFFICIENT QUANTITIES OF MOISTURE TO ENTER AND AFFECT THE OPERATION OF THE VEHICLE AIR BRAKE SYSTEM.

Consequence

FAILURE OF THE AIR BRAKE SYSTEM DUE TO MOISTURE COULD RESULT IN A CRASH.

Remedy

GILLIG, IN CONJUNCTION WITH GRAHAM-WHITE, WILL REPLACE THE AIR DRYER TIMER MODULE ON THE AFFECTED VEHICLES. THE RECALL BEGAN ON JANUARY 29, 2008. OWNERS MAY CONTACT GILLIG AT 1-510-785-1500 OR GRAHAM-WHITE AT 540-387-5620.

07V265000EngineJune 8, 2007 · 2 units

Defect

ON CERTAIN TRANSIT BUSES BUILT WITH CUMMINS ISM C876 ENGINES, THE ELECTRONIC CONTROL MODULE FAILS TO RECOGNIZE INPUTS OF THE VEHICLE ELECTRONIC CONTROL UNIT OR FROM A DRIVER ACTUATED DASH SWITCH THEREBY INCREASING THE RISK OF UNINTENDED (OR UNEXPECTED) ELEVATED EXHAUST TEMPERATURES.

Consequence

WHILE THIS CONDITION DOES NOT INVOLVE A RISK OF FIRE IN THE VEHICLE ITSELF, IT COULD PRESENT A FIRE HAZARD IN A SITUATION WHERE THE VEHICLE'S EXHAUST IS IN CLOSE PROXIMITY TO MATERIALS OR SUBSTANCES THAT CAN MELT, BURN, OR EXPLODE.

Remedy

CUMMINS, IN CONJUNCTION WITH GILLIG, WILL CONDUCT THE REMEDY CAMPAIGN. THE RECALL BEGAN ON JULY 31, 2007. OWNERS CAN CONTACT CUMMINS AT 1-800-343-7357 OR GILLIG AT 1-510-785-1500.

07V259000SteeringJune 7, 2007 · 291 units

Defect

ON CERTAIN TRANSIT BUSES, THE HYDRAULIC HOSE LOCATED IN THE ENGINE COMPARTMENT WAS MANUFACTURED INCORRECTLY WHICH COULD CAUSE A HYDRAULIC FLUID LEAK.

Consequence

HYDRAULIC FLUID LEAKAGE COULD LEAD TO A LOSS OF FLUID WHICH COULD AFFECT VEHICLE STEERING OR CREATE THE CONDITIONS FOR A POTENTIAL ENGINE COMPARTMENT FIRE.

Remedy

GILLIG WILL PROVIDE CORRECT HOSES TO THEIR CUSTOMERS FOR REPLACEMENT OR WILL REPLACE THE HOSES FOR THEM. THE RECALL BEGAN ON JUNE 27, 2007. OWNERS MAY CONTACT GILLIG AT 1-510-785-1500.

2007 Gillig Low Floor — common questions

Is the 2007 Gillig Low Floor reliable?

The record is thin — 0 NHTSA complaints — so owner-report data can't strongly confirm reliability either way, though 8 recalls should be verified as completed.

Does the 2007 Gillig Low Floor have recalls?

Yes — NHTSA lists 8 recall campaigns affecting the 2007 Gillig Low Floor. Recall repairs are free at franchised dealers; check the VIN at nhtsa.gov/recalls to confirm the work was done.

Related

Based on NHTSA ODI data through June 2026. Complaints are consumer-reported and unverified. Updated July 5, 2026.

Compiled by Sharon Ben-Moshe, Founder.