Does the 2010 Gillig Low Floor have recalls?

9 NHTSA recall campaigns on file. Recall repairs are free at franchised dealers.

18V418000LightingJune 20, 2018 · 25,579 units

Defect

Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."

Consequence

The reduced visibility of the turn signals can increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

17V119000LightingFebruary 24, 2017 · 17,056 units

Defect

Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."

Consequence

The reduced visibility of the turn signals may increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

16V011000SeatsJanuary 13, 2016 · 6,734 units

Defect

Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.

Consequence

If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.

Remedy

Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

15V420000Electrical SystemJuly 1, 2015 · 6,971 units

Defect

Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.

Consequence

If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.

Remedy

Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

15V262000EngineMay 5, 2015 · 1,101 units

Defect

Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.

Consequence

If engine oil comes into contact with a hot surface, there is an increased risk of a fire.

Remedy

Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 2, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

14V358000EngineJune 23, 2014 · 648 units

Defect

Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.

Consequence

If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.

Remedy

Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1-800-735-1500.

14V084000EngineFebruary 27, 2014 · 643 units

Defect

Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.

Consequence

The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.

Remedy

Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1-510-785-1500 or Cummins Inc. at 1-800-343-7357.

12V506000Visibility & WipersOctober 18, 2012 · 657 units

Defect

Gillig is recalling certain model year 2010 Lowfloor transit buses, manufactured April 16, 2010, through November 16, 2010, and equipped with Ricon 3-Minute Urban Transit Bus Window sets. The composition of the material used to cast the handle that opens the egress window is incorrect, resulting in a reduction in material strength. The handle(s) on the emergency egress passenger windows may break before the window latch is released.

Consequence

In the event the egress window handle fails during an actual emergency situation, passengers may be trapped in the vehicle placing them at risk of injury.

Remedy

Gillig will notify owners, and dealers will replace the window handles free of charge. The recall began during October 2012. Owners may contact Gillig at 1-800-735-1500 for more information.

11V411000EngineAugust 10, 2011 · 563 units

Defect

GILLIG IS RECALLING CERTAIN MODEL YEAR 2010-2011 LOWFLOOR BUSES EQUIPPED WITH CUMMINS ENGINES. THE V-BAND CLAMP ASSEMBLY USED TO CONNECT THE INLET AND OUTLET CONE SECTIONS TO THE DIESEL OXIDATION CATALYST (DOC) DIESEL PARTICULATE FILTER (DPF) INCLUDE A T-BOLT WHICH CAN FRACTURE AND FAIL WHEN SUBJECTED TO STRESS OR LOAD. A FRACTURE OR FAILURE OF THE T-BOLT MAY CAUSE THE CLAMP TO LOOSEN AND THE INLET OR OUTLET SECTIONS ATTACHED TO THE DOC/DPF HOUSING TO DISCONNECT.

Consequence

IF THE INLET OR OUTLET SECTIONS DISCONNECT, HOT EXHAUST GASES CAN VENT PRIOR TO EXITING THE TAILPIPE, CREATING THE RISK OF COMBUSTION AND A FIRE. IF BOTH CLAMPS FAIL, THERE IS A RISK IN SOME APPLICATIONS THAT THE DOC/DPF HOUSING MAY DETACH COMPLETELY, CREATING A ROAD HAZARD.

Remedy

GILLIG IS WORKING WITH CUMMINS TO IDENTIFY OWNERS. CUMMINS IS HANDLING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN PLEASE SEE NHTSA RECALL 11E-031. OWNERS MAY CONTACT CUMMINS AT 1-812-377-5000.

2010 Gillig Low Floor — common questions

Is the 2010 Gillig Low Floor reliable?

The record is thin — 0 NHTSA complaints — so owner-report data can't strongly confirm reliability either way, though 9 recalls should be verified as completed.

Does the 2010 Gillig Low Floor have recalls?

Yes — NHTSA lists 9 recall campaigns affecting the 2010 Gillig Low Floor. Recall repairs are free at franchised dealers; check the VIN at nhtsa.gov/recalls to confirm the work was done.