VehicleVerdict

2019 Gillig Low Floor problems

Verdict · NHTSA data

Limited data — recalls on file

NHTSA has just one complaint on file for the 2019 Gillig Low Floor — too few to judge reliability from owner reports alone — but 12 recall campaigns apply to this year, so any used example should have its VIN checked for completed recall work.

1

NHTSA complaints

12

Recalls

0

Investigations

0

Crash-involved

0

Fires reported

0

Injuries

0

Deaths

NCAP overall

How does 2019 compare to other Low Floor years?

See all Low Floor years to avoid →

What are the most common 2019 Gillig Low Floor problems?

ComponentComplaintsShare
Seat Belts1100%

Does the 2019 Gillig Low Floor have recalls?

12 NHTSA recall campaigns on file. Recall repairs are free at franchised dealers.

25V076000OtherFebruary 11, 2025 · 91 units

Defect

Gillig, LLC (Gillig) is recalling certain 2019-2024 Low Floor transit buses. The rivet-nut fasteners that secure the TFT flat panel display monitor to the bus ceiling may fail, causing the monitor to detach and fall.

Consequence

A monitor that detaches and falls from the ceiling increases the risk of injury.

Remedy

Gillig will replace the rivet-nut fasteners, free of charge. Owner notification letters were mailed March 18, 2025. Owners may contact Gillig customer service at 1-800-735-1500.

23V740000TransmissionNovember 3, 2023 · 4,286 units

Defect

Gillig, LLC (Gillig) is recalling certain 2019-2023 Low Floor transit buses. The transmission yoke may separate, resulting in driveshaft separation and a sudden loss of drive power.

Consequence

A sudden loss of drive power can increase the risk of a crash. Additionally, a disabled bus may require an evacuation procedure in an uncontrolled traffic situation, increasing the risk of injury to passengers.

Remedy

Gillig will work with the equipment manufacturer, Allison Transmission Inc., to inspect and tighten the transmission yoke bolts, as necessary, free of charge. Owner notification letters were mailed December 11, 2023. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

22V548000Electrical SystemJuly 28, 2022 · 184 units

Defect

Gillig, LLC (Gillig) is recalling certain 2019-2022 Low Floor vehicles equipped with Cummins BP74E battery packs. The battery packs may develop a coolant leak internally, causing the battery pack to short circuit.

Consequence

A battery short circuit increases the risk of a fire.

Remedy

Gillig will tighten the coolant fittings and replace the coolant, free of charge. Owner notification were mailed on August 16, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 or 1-800-735-1500.

22V436000Electrical SystemJune 17, 2022 · 169 units

Defect

Gillig, LLC (Gillig) is recalling certain 2019-2022 Low Floor electric transit buses. The EV resolver cable connector may experience a loss of electrical connectivity, unexpectedly switching from Drive to Neutral with no warning.

Consequence

An unexpected switch to neutral can cause a loss of vehicle propulsion and increase the risk of a crash.

Remedy

Dealers will install a redesigned resolver cable with extended length and a new support bracket, free of charge. Owner notification letters were mailed on August 3, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 or 1-800-735-1500.

22V276000Electrical SystemApril 25, 2022 · 592 units

Defect

Gillig, LLC (Gillig) is recalling certain 2014-2021 Low Floor transit buses. The rear-mounted ultracapacitors may allow the engine to be started when the master battery disconnect switch is in the "OFF" position.

Consequence

The engine may be started unexpectedly, increasing the risk of injury to anyone nearby the engine compartment during maintenance operations.

Remedy

Dealers will update the software for the buses equipped with the Vanner Ultracapacitor system, and conduct a hard rewire for the buses equipped with the KBI system, free of charge. Owner notification letters were mailed on June 22, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 for 1-800-735-1500.

21V352000Fuel SystemMay 14, 2021 · 4,428 units

Defect

Gillig, LLC. (Gillig) is recalling certain 2017-2020 Low Floor vehicles. The sealing washer may not seat correctly in the pilot bore holes, allowing the high pressure fuel rail assembly to leak.

Consequence

A fuel leak in the presence of an ignition source increases the risk of a fire.

Remedy

Gillig will inspect the rail threads, and replace the rail as necessary, free of charge. Owner notification letters were mailed on August 27, 2021. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

20V392000SteeringJuly 2, 2020 · 531 units

Defect

Gillig, LLC. (Gillig) is recalling certain 2013-2020 hybrid and all-electric Low Floor buses equipped with a steering system that uses a high-voltage electric motor and hydraulic pump assembly to provide power steering assist. The shaft coupling between the motor and pump may fail and cause a loss of hydraulic power steering assist.

Consequence

A loss of power steering assist may increase the risk of crash.

Remedy

Gillig will notify owners, and dealers will replace the motor-pump assemblies, free of charge. The recall began August 13, 2020. Owners may contact Gillig customer service at 1-800-735-1500.

20V342000SuspensionJune 10, 2020 · 3,728 units

Defect

Gillig LLC (Gillig) is recalling certain 2018-2020 Low Floor buses. The rear suspension lower control rods may experience fatigue failure due to stiffened end bushings.

Consequence

If the rear suspension lower control rod fails, the bus may have reduced handling and stability, increasing the risk of a crash.

Remedy

Gillig will notify owners and provide them with new lower control rods with different bushings, free of charge. This recall began June 26, 2020. Owners may contact Gillig customer service at 1-800-735-1500.

20V239000Fuel SystemApril 29, 2020 · 275 units

Defect

Gillig LLC (Gillig) is recalling certain 2018-2020 Low Floor transit buses powered by compressed natural gas (CNG). The thermally activated pressure relief device (PRD) installed on the CNG fuel system may not vent the system when exposed to heat, potentially resulting in the system rupturing.

Consequence

If the fuel system ruptures from exposure to heat, there may be an increased risk of injury.

Remedy

Gillig will work with Agility to notify customers and replace the PRDs, free of charge. The recall began May 15, 2020. Owners may contact Agility customer service at 1-949-267-7745 or Gillig customer service at 1-800-735-1500.

20V179000Electrical SystemMarch 25, 2020 · 8,224 units

Defect

Gillig LLC (Gillig) is recalling certain 2012-2020 Low Floor buses. The circuit breaker ratings on the DEF Line Heater circuit and the Aftertreatment-Ignition circuit may be higher than the rating for the wire and connector.

Consequence

With the improper circuit breaker rating, an electrical short in either of these circuits may increase the risk of a fire.

Remedy

Gillig will notify owners, and dealers will replace the circuit breakers, free of charge. The recall began April 24, 2020. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

19V451000Body & StructureJune 14, 2019 · 25 units

Defect

Gillig LLC (Gillig) is recalling certain 2018-2019 Low Floor vehicles equipped with a certain batch of glass roof hatches. Temperature and vibration stresses may cause the tempered glass roof hatch to shatter.

Consequence

If the tempered glass roof hatch shatters, glass fragments may fall onto passengers, increasing the risk of an injury.

Remedy

Gillig will notify owners, and the glass hatch manufacturer will provide replacement hatch lids, free of charge. The recall began June 27, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

19V193000LightingMarch 8, 2019 · 965 units

Defect

Gillig LLC (Gillig) is recalling certain 2014-2019 Low Floor buses. Uncovered electrical terminals in the headlight power circuit may short circuit to ground, causing a loss of headlights.

Consequence

A loss of headlights can reduce the driver's ability to see, increasing the risk of a crash.

Remedy

Gillig has notified owners, and dealers will install new back covers on the headlight buckets, free of charge. The recall began April 1, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Consumer complaints filed with NHTSA

Representative excerpts, cleaned of personal information. These are consumer statements, not verified defects.

I DRIVE BUSES FOR DISNEY WORLD AND THEY HAVE JUST GOT SOME NEW BUSES WITH NEW SEATS AND TWO PART SEAT BELTS. THE WAY THE LAP BELT AND SHOULDER BELT HOOK TOGETHER CAUSE THEM TO TWIST WHICH ALLOWS THE SHOULDER BELT TO JAM IN THE RETURN GUIDE NOT ALLOWING THE BELT TO FULLY RETRACT AND HOLD PROPERLY.I…

Complaint filed with NHTSA · Seat Belts · August 8, 2019

2019 Gillig Low Floor — common questions

Is the 2019 Gillig Low Floor reliable?

The record is thin — 1 NHTSA complaint — so owner-report data can't strongly confirm reliability either way, though 12 recalls should be verified as completed.

Does the 2019 Gillig Low Floor have recalls?

Yes — NHTSA lists 12 recall campaigns affecting the 2019 Gillig Low Floor. Recall repairs are free at franchised dealers; check the VIN at nhtsa.gov/recalls to confirm the work was done.

Related

Based on NHTSA ODI data through June 2026. Complaints are consumer-reported and unverified. Updated July 5, 2026.

Compiled by Sharon Ben-Moshe, Founder.